Battery Storage System CB2450N
- Easy configurations of battery systems of 12v or 24v voltage multiples.
- Parallel battery branches for higher system currents.
- Minimal lead time for establishing a new battery system.
- Capable of configuring high voltage (up to 400v+) and/or high current (up to 264a+) battery systems.
- Built-in thermal management.
- Real time monitoring of cell voltages, branch currents, and cell temperatures via Rs485 Bus.
- Extended availability thru parallel battery branches with independent branch controls.
- Stable & reliable name-brand battery cells from fully automatic production lines.
FSP Configurable Batteries
CB Series use FSP advanced BMS to enhance system performance, prolong life, and warrant safety. FSP BMS also constructed in modular form for flexible and easy configuration of larger battery systems. Three types of modules exists as below.
BM, Battery Module: consists of battery cells and control portion of BMS.
IM, Integrated Module: consists of battery cells and both control and power portions of BMS.
PM, Power Module: consists of no battery cells but the control and power portions of BMS for high power battery systems.
IM, Integrated Module: consists of battery cells and both control and power portions of BMS.
PM, Power Module: consists of no battery cells but the control and power portions of BMS for high power battery systems.
To facilitate uses with different battery cells or battery packs in different form factors preferred by customers the BMS for the IM, BM and PM are also available to the customers without the cases and battery cells.
Active Cell Balance & Active Block Balance
RS485 communication bus
Applications
51.2V 66Ah LiFePo4 Batteries
Specifications
Module Type | IM | BM | PM |
Model Name | CB2450Nlx* | CB2450N#** | CP45P0 |
Cell Type | Li-ion | ||
Nominal Voltage (V) | 25.3 | ||
Maximum Charge Cut Off Voltage or |
|
| |
Minimum Discharge Cut Off Voltage (V) | 19.6 | ||
Rated Capacity (Wh) | 1308 | ||
Nominal Charging Current (A) | 26 | ||
Maximum Charging Current (A) | 52 | ||
Rated Discharging Current or |
|
| |
Charging Voltage (V) | 29.4 | ||
Operating Temperature- Charge* (℃) | 0-50 | 0-60 | |
Operating Temperature- Discharge* (℃) | -20-60 | 0-60 | |
Cell Balancing Between Cells | 0.2A Passive | ||
Cell Balancing Between Modules | 1.25A Active | ||
Weight (kg) | 10* | 2.6 | |
Regulatory | IEC 62133/CE | ||
* x=A for system voltage up to 72V, x=B for system voltage greater than 72V and up to 144V. For latter external heatsink is needed which adds about 0.8kg in weight.
** #=1 for use in system with voltage up to 144V; #=2 for use in systems with voltage up to 450V.
** #=1 for use in system with voltage up to 144V; #=2 for use in systems with voltage up to 450V.
Specifications
Model | CB2450N#** |
---|---|
Dimensions(Lx W x H) | 285 x 168 x 175 mm |
Battery Protections | Over-Charge, Over-Discharge, Over-Temperature, Under-Temperature, Over-Current, Short-Circuit |
Communication Bus | RS485, other (RS232, CAN-bus, Ethernet, USB) Optical |
Parameters for Monitoring | Voltages, Temperature, Currents, Capacity |
Environment | IPx3, RoHS |